How Does Mission Time Work with Proof Testing to Impact SIL Verification?
2 October 2024
I have been asked this question many times by various clients over the years. This comes down to whether a perfect proof test is assumed or not. Let us remember that Mission Time is defined as the amount of time we expect a set of SIF equipment to run until a major overhaul is required, usually based upon the useful life of the devices. This time is set by the end user. Some companies are still not appreciating how greatly they will overstate the risk reduction of the Safety Instrumented Function (SIF) by assuming perfect proof testing since Mission Time then has no impact.
Therefore, what is perfect proof testing and what does this mean? We will discuss this among other things in this webinar.
Please Note: exida Webinars no longer support Internet Explorer. Please use another web browser such as Edge or Chrome.
Session 1: 10:00 - 11:00 AM EDT
Sign Up
Session 2: 4:00 - 5:00 PM EDT
Sign Up
About the Presenter:
Steve Gandy, CFSP
Steve Gandy joined exida as VP of Global Business Development, from Metso, bringing with him 35 years of experience of industrial controls and safety experience. He was responsible for sales and operations in Asia for Metso, setting up their India subsidiary and China energy and process team. Steve was also responsible for managing Metso’s VAR partners in the region, as well as developing new markets in Vietnam, Egypt, Indonesia, Ukraine and Guam.