exida - Functional Safety Services, IACS Cybersecurity, Alarm Management, IEC 61508 Certification

Search

20 results for the keyword search: ""

White Paper: Random versus Systematic Failures – Issues and Solutions

Functional safety standards provide definitions of two different categories of failures: random failures and systematic failures. These were created during the standards committee discussions of failure types to be modeled in the probabilistic failure analysis. It was decided that random failures are counted in the probabilistic failure rate analysis and…


Training Course: Fire and Gas Detection Design and Technology

This course is developed by an exida certified training provider. It provides attendees a comprehensive understanding of all aspects of Fire and Gas Detection Technology; from performance based design (fire and gas mapping) through to practical maintenance requirements, including: Role & Action of Fire & Gas Detection Performance Requirements Design…


Blog Entry: The Crossroads of Alarm Management and Process Safety

Recently I was reading The Manufacturing Operations Technology Viewpoints blog and came across an interest post on Alarm Management that cites exida’s Alarm Management cheat sheet. The blog post entitled The Crossroads of Alarm Management and Process Safety is a great summary for any one who needs a primer on…


Service: Process Hazard Analysis (PHA) Facilitation

The main objective of a Process Hazards Analysis (PHA) is to identify potential hazards posed by the process and associated equipment. The PHA is the first step in the functional safety lifecycle. This first step is critical, as adequate risk reduction measures cannot be implemented for hazards that are not…


News Item: exida Announces Two New China Based Subsidiaries

exida is pleased to announce the formation of two new China based subsidiaries, exida Safety Systems (Shanghai) Co., Ltd. and exida (Qingdao) Industrial Safety Technology Co., Ltd. As a subsidiary of exida GmbH, exida Safety Systems (Shanghai) Co., Ltd. in China will focus on the automotive industry and other emerging…


Service: HAZOP Facilitation

HAZOP stands for Hazard and Operability study. HAZOP is a process hazards analysis procedure originally developed by ICI in the 1970s. The method is highly structured and divides the process into different operationally-based nodes and investigates the behavior of the different parts of each node based on an array of…


News Item: exida Asia Pacific Presenting Paper at Chemical Industry Hazard Analysis and Risk Management Seminar

Clarence Liew from exida Asia Pacific will be presenting a paper, “Common Pitfalls in PHA and SIL Assessments and How to Avoid Them”, at the 5th Chemical Industry Hazard Analysis and Risk Management Seminar organized by the China Chemical Safety Association to be held September 22-23, 2016 in Tianjin, China.


KVC (UK) Ltd. - Trunnion Mounted Ball Valves

IEC 61508 in the Safety Automation Equipment List


KVC (UK) Ltd. - Floating Ball Valves

IEC 61508 in the Safety Automation Equipment List


Blog Entry: Introduction to ICS Security - Pt. 2 - IT versus ICS Security

Over the next couple of blogs, I plan to map out the importance of ISA/IEC-62443/ISA-99 based cybersecurity and how it applies to your work environment. I'll also explain some of our services so that you can see what might pertain to you. For part 1 , I started from the…


Yokogawa Electric Corporation - YTA710 & YTA610 Temperature Transmitter

IEC 61508 in the Safety Automation Equipment List


Blog Entry: How Secure Is Your Safety Instrumented System 〈SIS〉?

As the cybersecurity threats in the industrial world continue to rise, the automation world continues to grapple with how to address these issues. As such, the newly released IEC61511-1: 2016 edition has included a new clause to address this (Clause 8.2.4). In essence, End Users have to carry out a…


ASCO, L.P. - Series 364 Solenoid Valves

IEC 61508 in the Safety Automation Equipment List


Blog Entry: FMEDA Predictions

The FMEDA technique is performed on a specific device (e.g., ball valve, pressure transmitter, temperature sensor, electronic module, etc.) specified down to the manufacturer and series/model. Based on the specifics of the design, the parts used to execute the design, the design margins, any automatic diagnostics, the specific use and…


White Paper: Properly Assessing Diagnostic Credit in Safety Instrumented Functions Operating in High Demand Mode

According to the basic functional safety standard IEC61508:2010 Part 2 [1], when assessing the safety performance of a safety instrumented function (SIF) operating in high demand mode, full credit can be given for the positive effects of automatic self‐diagnostics (ASD) in SIF devices provided the frequency of ASD execution is…


Blog Entry: Introduction to ICS Security - Pt. 1 - What is ICS Security and Why it Is Important

Over the next couple of blogs, I plan to map out the importance of ISA/IEC-62443/ISA-99 based cybersecurity and how it applies to your work environment. I'll also explain some of our services so that you can see what might pertain to you. For part 1, I will start from the…


Autronica Fire and Security AS - HC800 Infrared Gas Detector

IEC 61508 in the Safety Automation Equipment List


TechnipFMC - Shallow E3 Actuated Gate Valve

IEC 61508 in the Safety Automation Equipment List


TechnipFMC - E3 Actuated Gate Valve

IEC 61508 in the Safety Automation Equipment List


FMC Technologies Singapore Pte Ltd - HYT Series 80, 120, 155 & 175

IEC 61508 in the Safety Automation Equipment List


Page 84 of 146 pages. ‹ First  < 82 83 84 85 86 >  Last ›